Robotic Transjugular Transcatheter Tricuspid Valve Replacement

Recruiting now · Not applicable

Conditions studied: Tricuspid Regurgitation (TR), Valvular Heart Diseases, Transcatheter Valve Replacement

In brief

Valvular heart disease (VHD), caused by abnormalities in heart valves, can lead to severe complications such as heart failure and death, with approximately 220 million affected patients worldwide. The prevalence of VHD continues to grow alongside the aging global population. Transcatheter heart valve interventions have emerged as minimally invasive alternatives, offering benefits like shorter recovery times and reduced discomfort. However, current manual catheter-based techniques are complex, highly dependent on clinicians' expertise, and involve significant physical risk due to prolonged exposure to X-ray radiation and cumbersome protective gear. To address these challenges, a novel, universal intracardiac robotic system is proposed to improve precision, safety, and procedural efficiency. This system integrates a high-dexterity, load-capacity catheter instrument, a modular concentric robotic platform, and an augmented reality (AR) navigation interface. The catheter's design balances flexibility for navigating complex intracardiac paths with the rigidity needed for device deployment. The robotic platform's modular architecture enhances versatility, enabling control across various procedures and anatomical variations, while the AR system facilitates intuitive preoperative planning and real-time intraoperative guidance through multimodal image fusion. The core innovation lies in overcoming existing limitations: balancing catheter flexibility and load capacity, expanding robotic system adaptability for different valve procedures, and improving integration with imaging modalities like computed tomography, transesophageal echocardiogram, and fluoroscopy. The project aims to develop sophisticated models for instrument design, control strategies for multi-instrument coordination, and advanced navigation tools. These technological advancements are intended to elevate the clinical utility of robotic intracardiac interventions, making them safer, more efficient, and easier to adopt widely. By establishing a systematic approach for intelligent, multimodal, robotic-assisted valvular procedures, this work promises significant contributions to minimally invasive cardiology and holds substantial potential for clinical translation.

Key facts

Study ID
NCT07516145
Run by
Prince of Wales Hospital, Shatin, Hong Kong
People needed
10
Starts
2026-03-12
Expected to finish
2028-03-31
Last updated by the study team
2026-04-07

Who can join

Age: 18 and older, up to 90. Sex: any. Healthy volunteers: not accepted.

You may qualify if…

You may not qualify if…

Where it is running

Full record on ClinicalTrials.gov

Trial information comes from ClinicalTrials.gov and is refreshed daily. TrialsForMe does not provide medical care and does not run the studies it lists.