Study on the Trans-Carotid Artery Occlusion Shunt System Combined With Introducer Sets
Recruiting now · Not applicable
Conditions studied: Carotid Artery Stenosis, Carotid Artery Diseases
In brief
The objective of the study is to evaluate the Safety and Efficacy of the Trans-Carotid Artery Occlusion Shunt System Combined with Introducer Sets for Cerebral Protection During Carotid Angioplasty
Key facts
- Study ID
- NCT06959628
- Run by
- Shenzhen Wecan Medical Technology Co.,Ltd
- People needed
- 15
- Starts
- 2024-07-01
- Expected to finish
- 2025-06-01
- Last updated by the study team
- 2025-05-06
Who can join
Age: 18 and older. Sex: any. Healthy volunteers: not accepted.
You may qualify if…
- Age ≥ 18 years;
- Patients with internal carotid artery stenosis, meeting at least one of the following conditions:
- Asymptomatic carotid artery stenosis: Stenosis severity > 70%;
- Symptomatic carotid artery stenosis: Stenosis severity > 50%, with one or more of the following symptoms occurring within 180 days prior to the procedure: transient ischemic attack (TIA), transient visual obscurations (TVO), or mild/non-disabling stroke;
- Common carotid artery diameter > 6 mm, and meets the required vascular diameter for carotid artery stenting;
- The participant or their legal guardian is able to understand the purpose of the trial, voluntarily consent to participation, sign an informed consent form, and is willing to comply with follow-up requirements as outlined in the study protocol.
You may not qualify if…
- Anatomical Exclusion Criteria:
- Patients with extensive atherosclerotic plaques in the proximal common carotid artery, which hinder safe surgical manipulation;
- Patients with lesions in the common carotid artery access area or its proximal segment;
- Patients with the common carotid artery bifurcation located < 5 cm from the clavicular margin;
- Patients with tandem severe stenosis or occlusion at the target lesion site;
- Patients who have previously received stent or graft implantation in the ipsilateral carotid artery;
- Patients with bilateral carotid artery stenosis requiring intervention on both sides;
- Patients with acute or subacute thrombosis, arteriovenous malformations, or other abnormal vascular structures in the target lesion or adjacent regions;
- Patients with severe calcification or tortuosity at the target lesion site, making it difficult to deliver devices to the intended location;
- Patients with concomitant severe symptomatic stenosis in other vascular territories, including intracranial or extracranial arteries;
- Patients who have experienced an ischemic stroke within the past 3 months, which may impact endpoint evaluation;
- Patients with a history of spontaneous intracranial hemorrhage within the past 12 months;
- Patients diagnosed with carotid artery dissection;
- Patients with carotid stenosis due to non-atherosclerotic causes;
- Patients with other cardiovascular conditions that may predispose to embolism, including left ventricular aneurysm, cardiomyopathy, mechanical aortic or mitral valves, infective endocarditis, mitral stenosis, atrial septal defect, atrial septal aneurysm, or left atrial myxoma;
- Patients with central nervous system disorders, including cranial nerve impairment, which could confound endpoint evaluation (e.g., severe dementia, secondary epilepsy, etc.);
- Patients with chronic atrial fibrillation;
- Patients with paroxysmal atrial fibrillation episodes within the past 6 months or those requiring long-term anticoagulation therapy due to paroxysmal atrial fibrillation;
- Patients who have had a myocardial infarction within the last 6 months;
- Patients who have undergone or plan to undergo coronary artery bypass grafting (CABG), endovascular stenting procedures, or heart valve surgeries within 90 days prior to the procedure, which may interfere with endpoint evaluation;
- Patients with active bleeding tendencies or significant coagulation disorders;
- Patients with a history of gastrointestinal bleeding that could interfere with antiplatelet therapy;
- Patients with preoperative liver or renal dysfunction, defined as alanine aminotransferase (ALT) or aspartate aminotransferase (AST) levels exceeding 5 times the upper limit of normal, or serum creatinine (Cr) > 3.0 mg/dL (265.2 μmol/L);
- Patients with known hypersensitivity to contrast agents, anticoagulants, antiplatelet medications, or materials used in stent delivery systems (e.g., nitinol, PTFE, nylon-based polymers);
- Patients with intracranial or other malignancies;
Where it is running
- Beijing Anzhen Hospital — Beijing, China (enrolling)
Full record on ClinicalTrials.gov
Trial information comes from ClinicalTrials.gov and is refreshed daily. TrialsForMe does not provide medical care and does not run the studies it lists.