Impact of Robotic Cochlear Implantation on Hearing Performance in Noise
Recruiting now · Not applicable
Conditions studied: Severe to Profound Hearing Loss
In brief
The purpose of this study is to compare two methods of cochlear implantation : conventional manual insertion versus robot-assisted in order to verify whether robotic insertion provides better performance in the noisy environment. To do this, we will compare the two methods of insertion of the electrode holder, on 140 patients candidates for cochlear implantation randomized in two groups (70 conventional surgery versus 70 robot-assisted surgery). All patients will be recruited during 17 months, in our Ear, nose and throat (ENT) Department of the Pitié-Salpêtrière hospital group, the first center for adult patients established in France (on average 180 patients/year). Patient will be followed for 9 months with clinical evaluation, imaging, audiometric, listening effort and quality of life assessments. These evaluations will be carried out preoperatively and postoperatively at 3 months and 6 months post-activation of the cochlear implant.
Key facts
- Study ID
- NCT06248398
- Run by
- Assistance Publique - Hôpitaux de Paris
- People needed
- 140
- Starts
- 2024-02-20
- Expected to finish
- 2025-12-01
- Last updated by the study team
- 2025-02-17
Who can join
Age: 18 and older. Sex: any. Healthy volunteers: not accepted.
You may qualify if…
- Adult patient ≥ 18 years old
- Patients with an indication for uni or bilateral, simultaneous or sequential cochlear implantation: severe to profound bilateral deafness with intelligibility ≤70% for Fournier dissyllabic words, in free field, at 60dB with adapted hearing aids.
- Patient able to understand the information note and give written consent
- Affiliation to a French social security system
You may not qualify if…
- Patient who does not speak French
- Etiologies of deafness known to be of bad prognosis (auditory neuropathy, congenital profound deafness, immediate post-meningitis profound deafness, vestibular schwannoma on the side of the ear to be implanted)
- Impossibility of testing the effect of the cochlear implant alone on hearing results (cochlear implantation in the context of unilateral deafness or fluctuating deafness)
- Cochlear implantation requiring the use of a perimodiolar electrode holder.
- Pregnant and breastfeeding women
- Patients wearing electronic devices, in direct connection with the brain or nervous system
- Patient included in another interventional study (Jardé 1)
- Patient under legal protection (guardianship or curatorship) or deprived of liberty
Where it is running
- Groupe Hospitalier Pitié-Salpêtrière — Paris, France (enrolling)
Full record on ClinicalTrials.gov
Trial information comes from ClinicalTrials.gov and is refreshed daily. TrialsForMe does not provide medical care and does not run the studies it lists.