To Evaluate the Safety and Clinical Performance of the ARCHIMEDES Biodegradable Biliary and Pancreatic Stent
Recruiting now
Conditions studied: Obstructed Biliary and Pancreatic Duct
In brief
Significant experience with biodegradable materials has been reported in the orthopedic literature; in particular; biodegradable stents have been used in the endovascular and urologic epithelium. Stents are typically made from polymeric materials including Polylactic Acid (PLA), Polyglycolide (PGA), Polydioxanone (PDO), Polyethyleneglycol (PEG), Polycaprolactone (PCL), etc., which have been cleared or approved by the FDA and CE-marked as drug carriers, sutures, and bone fixatives. The material is degraded by hydrolysis in, e.g., lactic acid, which is removed from the body by normal metabolic pathways. In the field of gastroenterology, these stents were first introduced in patients with an esophageal stenosis with encouraging results, although esophageal hyperplasia was a frequently encountered complication. For biliary applications, biodegradable stents have been evaluated in several in-vitro and animal studies that demonstrated that the stents were safe and well tolerated. These stents provided an adequate radial force and resulted in complete stricture resolution within several months. The stents did not show any signs of biliary hyperplasia or integration in the epithelium. Moreover, they seem to have a self-clearing effect on attached biofilm as the outer layer sloughs during the degradation process similarly to the exfoliation of human skin. Also, the stent could be removed from the bile duct, thus offering the possibility of extraction if necessary at various times after implantation. In 2010, Petryl was the first to use a biodegradable stent in the human bile duct. A stent was successfully placed using percutaneous transhepatic cholangiograpy in two patients with a postsurgical intrahepatic biliary stricture. Transient cholangitis was the only complication encountered and during the two years of follow-up, the bile duct remained patent. Later, Mauri et al. presented in 2013 and 2016 results of a 107 patient study on a polydioxanone biodegradable biliary stent. The results have been published in the Journal of the European Society of Radiology. The authors concluded that percutaneous placement of a biodegradable biliary stent is a feasible and safe strategy to treat benign biliary strictures refractory to standard bilioplasty, with promising results in the mid-term period. Prior to this study, the ARCHIMEDES device was assessed in the ARCHIMEDES Investigational study which has completed enrolment with 53 patients included, and the results are not yet published. In this study approximately half the stents were deployed in the bile duct (53%) and half in the pancreatic duct. All 53 patients have either completed, exited, or no longer have the study device. No patient remains in the study with a stent in place during the time of the last patient follow-ups. The study concluded without any device-related SAE. Bilirubin was reduced by 25.6%, which exceeded the \>20% clinical success criterion, quality of life score improved from 3.7 to 7.9, procedural success was rated 1.4 (good to excellent), and technical success was achieved in all 53 patients. Data from the ARCHIMEDES Investigational study was used for CE Mark approval, which was obtained in June 2018.
Key facts
- Study ID
- NCT04708288
- Run by
- QualiMed Innovative Medizinprodukte GmbH
- People needed
- 198
- Starts
- 2020-10-03
- Expected to finish
- 2027-12-31
- Last updated by the study team
- 2026-06-30
Who can join
Age: 18 and older. Sex: any. Healthy volunteers: not accepted.
You may qualify if…
- Patient eligible for implantation of a pancreatic or billiary stent prior to participate in the study and according to current guidelines
- Patient has provided a signed and dated informed consent (according to the laws and regualtions of the country in which the observational study is conducted)
You may not qualify if…
- Age < 18 y
- Inability to understand the purpose of the study or refusal to cooperate
- Not available for routine follow-up visits
- Pregnancy
- Currently participating in a confounding trial before reaching first endpoint.
Where it is running
- Evangelisches Krankenhaus Düsseldorf — Düsseldorf, Germany (enrolling)
- University Medical Center Ljubljana — Ljubljana, Slovenia (enrolling)
- Hospital Universitario de Salamanca — Salamanca, Spain (enrolling)
- Endoscopy Unit, Humanitas Research Hospital — Rozzano, Milano, Italy
- HUS Helsinki University Hospital — Helsinki, Finland
- Gastroenterology and Digestive Endoscopy Unit Fondazione I.R.C.C.S. Policlinico San Matteo — Pavia, Italy
- UCBM - Campus Bio-Medico University — Roma, Italy
- Tan Tock Seng Hospital Pte Ltd, — Singapore, Singapore
- AUSL Romagna Ospedale Morgagni - Pierantoni — Forlì, Italy
- Hôpital Européen Georges-Pompidou HEGP Service d'Hépato-gastro-entérologie et endoscopies digestives — Paris, France
- Emek Medical Center — Afula, Israel
Full record on ClinicalTrials.gov
Trial information comes from ClinicalTrials.gov and is refreshed daily. TrialsForMe does not provide medical care and does not run the studies it lists.