Valiant Evo US Clinical Trial
Completed · Not applicable
Conditions studied: Aortic Aneurysm, Thoracic
In brief
The purpose of the Valiant Evo US Clinical Trial is to demonstrate the safety and effectiveness of the Valiant Evo Thoracic Stent Graft System in subjects with a descending thoracic aortic aneurysm (DTAA) who are candidates for endovascular repair.
Key facts
- Study ID
- NCT02652949
- Run by
- Medtronic Cardiovascular
- People needed
- 100
- Starts
- 2016-04-01
- Expected to finish
- 2023-03-02
- Last updated by the study team
- 2024-04-09
Who can join
Age: 18 and older. Sex: any. Healthy volunteers: not accepted.
You may qualify if…
- Subject is ≥18 years old.
- Subject understands and voluntarily has signed and dated the Informed Consent Form approved by the Sponsor and by the Ethics Committee for this study.
- Subject presents a Descending Thoracic Aortic Aneurysm (DTAA) which is localized below the ostium of Left Subclavian Artery (LSA) and above the ostium of celiac trunk
- Subject has a DTAA that is one of the following:
- A fusiform aneurysm with a maximum diameter that:
- is ≥ 50 mm and/or:
- is > 2 times the diameter of the non-aneurysmal thoracic aorta and/or:
- is < 50 mm and has grown ≥ 5 mm within previous 12 months
- A saccular aneurysm or a penetrating atherosclerotic ulcer
- Subject's anatomy must meet all of the following anatomical criteria as demonstrated on contrast-enhanced CT and/or on contrast-enhanced Magnetic Resonance Angiogram (MRA) obtained within four (4) months prior to implant procedure:
- Proximal and distal non-aneurysmal aortic neck diameter measurements must be ≥ 16 mm and ≤ 42 mm;
- Proximal non-aneurysmal aortic neck length must be ≥ 20 mm (for FreeFlo configuration) and ≥ 25 mm (for Closed Web configuration) distal to the left common carotid artery (LCCA). Note: Proximal aortic neck length may include covering the LSA (with or without discretionary revascularization) when necessary to optimize device fixation and maximize aortic neck length. If occlusion of the LSA ostium is required to obtain adequate neck length for fixation and sealing, transposition or bypass to the LSA may be warranted.
- Distal non-aneurysmal aortic neck length must be ≥ 20 mm
- Subject has adequate arterial access site or can tolerate a conduit that allows endovascular access to the aneurysmal site with the delivery system of the appropriate sized device chosen for the treatment.
You may not qualify if…
- Subject has a life expectancy of less than 1 year
- Subject is participating in another investigational drug or device study which would interfere with the endpoints and follow-ups of this study.
- Subject is pregnant.
- Subject requires planned placement of the covered proximal end of the stent graft to occur in zones 0 or 1.
- Subject has a thoracic aneurysm with a contained rupture or localized at the anastomosis of a previous graft (pseudo-/false aneurysm).
- Subject has a mycotic aneurysm.
- Subject has a dissection (type A or B) or an intramural hematoma or an aortic rupture in addition to the thoracic aneurysm.
- Subject requires emergent aneurysm treatment, e.g., trauma or rupture.
- Subject has received a previous stent or stent graft or previous surgical repair in the ascending and/or descending thoracic aorta, and/or in the aortic arch.
- Subject requires surgical or endovascular treatment of an infra-renal aneurysm at the time of implant
- Subject has had previous surgical or endovascular treatment of an infra-renal aortic aneurysm.
- Treatment with the Valiant Evo Thoracic Stent Graft would require intentional revascularization of the brachio-cephalic artery or the left common carotid artery or the celiac trunk.
- Subject has had or plans to have a major surgical or interventional procedure within 30 days before or 30 days after the planned implantation of the Valiant Evo Thoracic Stent Graft. This does not include planned procedures that are needed for the safe and effective placement of the stent graft (i.e., carotid/subclavian transposition, carotid/subclavian bypass procedure).
- Subject has a significant and/or circumferential aortic mural thrombus at either the proximal or distal attachment sites that could compromise fixation and seal of the implanted stent graft.
- Subject has a connective tissue disease (e.g., Marfan's syndrome, aortic medial degeneration).
- Subject has a bleeding diathesis or coagulopathy, or refuses blood transfusion.
- Subject has had a Myocardial Infarction (MI) within 3 months of the procedure.
- Subject has had a Cerebrovascular Accident (CVA) within 3 months of the procedure.
- Subject has a known allergy or intolerance to the device materials
- Subject has a known allergy to anesthetic drugs
- Subject has a known hypersensitivity or contraindication to anticoagulants, or contrast media, which is not amenable to pretreatment.
- Subject has active or systemic infection at the time of the index procedure.
Where it is running
- Abrazo Arizona Heart Institute — Phoenix, Arizona, United States
- Stanford Hospital — Stanford, California, United States
- Medstar Washington Hospital Center — Washington D.C., District of Columbia, United States
- University of Florida — Gainesville, Florida, United States
- Emory University Hospital — Atlanta, Georgia, United States
- University of Michigan Health System — Ann Arbor, Michigan, United States
- University of Minnesota Medical Center — Minneapolis, Minnesota, United States
- Barnes Jewish Hospital — St Louis, Missouri, United States
- Albany Medical Center — Albany, New York, United States
- University of North Carolina — Chapel Hill, North Carolina, United States
- Carolinas Medical Center — Charlotte, North Carolina, United States
- Duke University Medical Center — Durham, North Carolina, United States
- Cleveland Clinic — Cleveland, Ohio, United States
- Ohio State University — Columbus, Ohio, United States
- OhioHealth Riverside Methodist Hospital — Columbus, Ohio, United States
- University of Pennsylvania — Philadelphia, Pennsylvania, United States
- Memorial Hermann Texas Medical Center — Houston, Texas, United States
- The Heart Hospital Baylor Plano — Plano, Texas, United States
- University of Virginia Medical Center — Charlottesville, Virginia, United States
- Inova Fairfax Hospital — Falls Church, Virginia, United States
- Sentara Norfolk General Hospital — Norfolk, Virginia, United States
Full record on ClinicalTrials.gov
Trial information comes from ClinicalTrials.gov and is refreshed daily. TrialsForMe does not provide medical care and does not run the studies it lists.