Dynamic Locking Screws 5.0 vs. Standard Locking Screws in Fracture of Distal Femur Treated With Locked Plate Fixation
Stopped early · Phase 4
Conditions studied: Distal Femur Fractures
In brief
The purpose of this study is to evaluate the performance of Dynamic Locking Screws (DLS) used to stabilize the shaft component of distal femur fractures in comparison to standard locking screws (SLS). The hypothesis is that DLS will lead to better functional outcomes (WOMAC score) due to increased and more symmetrical callus formation and fewer non-unions.
Key facts
- Study ID
- NCT01693367
- Run by
- AO Innovation Translation Center
- People needed
- 5
- Starts
- 2012-09-01
- Expected to finish
- 2014-12-01
- Last updated by the study team
- 2020-08-13
Who can join
Age: 21 and older, up to 120. Sex: any. Healthy volunteers: not accepted.
You may qualify if…
- 21 years and older
- Closed or open distal femur fracture (AO 33 A1-3, 33 C1-3) including distal femur fractures above a total knee arthroplasty
- Ability to walk independently prior to injury
- Eligible for treatment with ORIF of the distal femur with a large fragment locking plate (LISS, LCP)
- Willing and able to comply with post-operative protocol and return for follow-up.
- Ability to understand the content of the patient information / informed consent form and participate in the clinical investigation
- Signed informed consent
You may not qualify if…
- Additional ipsi- or contralateral lower extremity fracture
- Any kind of implant at the ipsilateral proximal femur
- Pre-existing malunion or nonunion of the ipsilateral lower extremity
- Segmental bone defect requiring bone grafting
- More than 4 weeks between injury and surgery
- Pathologic fracture due to a disease other than osteoporosis (eg, tumor, metastasis)
- Polytrauma
- Active malignancy
- Any not medically managed severe systemic disease
- Recent history of substance abuse (ie, recreational drugs, alcohol) that would preclude reliable assessment
- Pregnancy or women planning to conceive within the study period
- Prisoner
- Participation in any other medical device or medicinal product study within the previous month that could influence the results of the present study
Where it is running
- UC Davis Medical Center — Sacramento, California, United States
- University of Missouri Orthopaedics — Columbia, Missouri, United States
- Washington University Orthopedics — St Louis, Missouri, United States
- Hospital of the University of Pennsylvania — Philadelphia, Pennsylvania, United States
- Harborview Medical Center — Seattle, Washington, United States
- Wilhelminenspital — Vienna, Austria
- Charité Berlin, Campus Virchow Klinikum — Berlin, Germany
- Universitätsklinikum des Saarlandes — Homburg, Germany
- BGU Tübingen — Tübingen, Germany
- Cantonal Hospital Chur — Chur, Switzerland
- Luzerner Kantonsspital — Lucerne, Switzerland
- Universitätsspital Zürich — Zurich, Switzerland
Full record on ClinicalTrials.gov