Cutting Balloon Study
Completed · Not applicable
Conditions studied: Pulmonary Artery Stenosis
In brief
The primary objective of this study is to evaluate the safety and efficacy of transcatheter Cutting Balloon therapy for branch pulmonary artery stenosis resistant to low pressure dilation.
Key facts
- Study ID
- NCT01205568
- Run by
- Boston Children's Hospital
- People needed
- 73
- Starts
- 2003-08-01
- Expected to finish
- 2009-09-09
- Last updated by the study team
- 2018-05-25
Who can join
Age: any. Sex: any. Healthy volunteers: not accepted.
You may qualify if…
- Patient Inclusion Criteria (Determined Prior to Cardiac Catheterization)
- a. At least 1 branch pulmonary artery stenosis referred for planned catheterization for PA dilation b. At least one of the following: i.greater than one half systemic right ventricular pressure ii. regional decrease in pulmonary blood flow by lung scan iii. elevated pulmonary artery pressures (> 20 mmHg MPAP) iv. cyanosis at least in part due to PA stenosis c. Informed consent of patient and/or parent/guardian; assent of mature minors d. Agreement to participate in protocol, including follow-up testing
- Vessel Inclusion Criteria (Determined During Cardiac Catheterization)
- Native pulmonary artery or branch which fails balloon dilation up to 8 ATM; as defined by failure to eliminate a waist
- Native pulmonary artery or branch with a balloon waist diameter less than 7.5 mm (i.e.,0.5 mm less than the largest available CB) with dilation at 8 ATM
- All eligible vessels that are dilated during the catheterization must be enrolled as study vessels; "off-study" use of Cutting Balloons or high pressure dilations in eligible vessels is not allowed.
You may not qualify if…
- Patient Exclusion Criteria (Determined Prior to Cardiac Catheterization)
- Prior pulmonary artery angioplasty or surgery on the vessel within the previous 6 weeks
- Pregnancy
- Vessel Exclusion Criteria (Determined During Cardiac Catheterization)
- Vessel with an aneurysm from a prior dilation or surgery, defined as a local enlargement of the vessel greater than 100% of the lumen diameter both proximally and distally to the aneurysm. The maximum aneurysm diameter and vessel lumen diameter proximal and distal to the aneurysm will be recorded. The location of the aneurysm relative to the angioplasty site will be determined and reported as proximal, distal, or in the region of waist formation.
- Prior stent placement associated with the obstruction
- i. balloon inflation for the purpose of expanding the diameter of the stent along its length with no residual waist proximal or distal to the stent edges ii. balloon inflation resulting in waist formation within the edges of a stent iii. dilation of a vessel through the cells of a stent c. Unifocalized nor non-unifocalized systemic to pulmonary artery collaterals. d. A vessel requiring therapy at a site not amenable to delivery or safe positioning of a Cutting Balloon device due to unfavorable anatomy as determined by the physician and based on as assessment of vessel angles, size, length, and proximity to other vessels.
Where it is running
- University of California at San Francisco — San Francisco, California, United States
- Children's Hospital Boston — Boston, Massachusetts, United States
- Duke University Medical Center — Durham, North Carolina, United States
- Children's Hospital, Philadelphia — Philadelphia, Pennsylvania, United States
- Children's Hospital of Pittsburgh — Pittsburgh, Pennsylvania, United States
- Texas Children's Hospital — Houston, Texas, United States
Full record on ClinicalTrials.gov
Trial information comes from ClinicalTrials.gov and is refreshed daily. TrialsForMe does not provide medical care and does not run the studies it lists.