Validation of a Novel Oscillometric-Based Algorithm for Determination of the Ankle-Brachial Index
Completed
Conditions studied: Peripheral Arterial Disease
In brief
Peripheral arterial disease (PAD) is a highly prevalent medical condition. Patients with PAD are usually diagnosed on the basis of the ankle-brachial index. The ankle-brachial index is the ratio of ankle pressure to arm pressure after measurement of blood pressures in the arms and legs using a Doppler device. The need for dedicated equipment and trained personnel, along with the time required to perform the test, have been identified as barriers to widespread implementation of ankle-brachial index screening. The use of automated oscillometric devices for blood pressure measurement has been applied to leg pressure measurement and determination of the ankle-brachial index with variable success. It will be beneficial to investigate a reliable oscillometric-based procedure that can accurately measure leg pressures for the ankle-brachial index across the entire spectrum of PAD severity. In a previous pilot study completed in 2009 (IRB 08-823), the investigators gathered data from N=60 subjects which allowed for mathematical analysis of oscillometric waveforms derived from the lower extremities as compared to Doppler-based measurements of blood pressure. We used signal processing analysis and regression techniques to develop a two-step algorithm which will allow for accurate interpretation of oscillometric waveforms in normal/mild vs. moderate/severely diseased limb and accurate calculation of ankle pressure across the spectrum of peripheral artery disease severity. This proposed project will validate this novel oscillometric ABI algorithm in a population of patients who have been identified as at risk for PAD and for whom screening ABI has been recommended by multiple professional organizations (AHA/ACC and American Diabetes Association). Arm, ankle, and toe pressure measurements will be made in the supine position using Doppler, oscillometric methods, and a photoplethysmographic sensor. The ankle-brachial index and toe-brachial index will be calculated.
Key facts
- Study ID
- NCT01165437
- Run by
- Summit Doppler Systems, Inc.
- People needed
- 161
- Starts
- 2010-10-01
- Expected to finish
- 2011-01-01
- Last updated by the study team
- 2011-02-24
Who can join
Age: 50 and older. Sex: any. Healthy volunteers: accepted.
You may qualify if…
- At least 70 years of age
- At least 50 years of age with a history of diabetes mellitus or tobacco smoking (>100 cigarettes in their lifetime)
- Ambulatory Outpatient
You may not qualify if…
- Unable to give informed consent
- Unable to lie supine for at least 15 minutes
- Known non-compressible vessels on prior laboratory studies (ABI>1.3 on either side)
Where it is running